Ir para o menu de navegação principal Ir para o conteúdo principal Ir para o rodapé

The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity

La reproducibilidad del gps de 1 hz en desplazamiento acíclico con intensidad intermitente





Seção
Artículos de Investigación

Como Citar
de Lima e Silva, L. ., Borba Neves, E. ., Valente dos Santos, L. A. ., Baptista Da Silva, J., Gomes de Souza Vale, R. ., & Moreira Nunes, R. de A. (2021). The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity: La reproducibilidad del gps de 1 hz en desplazamiento acíclico con intensidad intermitente. Archivos De Medicina (Manizales), 21(1), 85-91. https://doi.org/10.30554/archmed.21.1.3812.2021
Baixar Citação

Dimensions
PlumX

Como Citar

de Lima e Silva, L. ., Borba Neves, E. ., Valente dos Santos, L. A. ., Baptista Da Silva, J., Gomes de Souza Vale, R. ., & Moreira Nunes, R. de A. (2021). The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity: La reproducibilidad del gps de 1 hz en desplazamiento acíclico con intensidad intermitente. Archivos De Medicina (Manizales), 21(1), 85-91. https://doi.org/10.30554/archmed.21.1.3812.2021

Baixar Citação

##articleSummary.license##
Leandro de Lima e Silva
Eduardo Borba Neves
Luciano Alonso Valente dos Santos
Jurandir Baptista Da Silva
Rodrigo Gomes de Souza Vale
Rodolfo de Alkmim Moreira Nunes

Leandro de Lima e Silva,

MSc, Universidade do Estado do Rio de Janeiro. Rio de Janeiro, Brasil. 


Eduardo Borba Neves,

PhD. Universidade Tecnológica Federal do Paraná. Curitiba, Brasil. ORCID: 


Luciano Alonso Valente dos Santos,

PhD. Universidade Federal do Rio de Janeiro. Rio de Janeiro, Brasil. ORCID: 


Jurandir Baptista Da Silva,

MSc, Universidade do Estado do Rio de Janeiro. Rio de Janeiro, Brasil. ORCID: 


Rodrigo Gomes de Souza Vale,

PhD. Universidade do Estado do Rio de Janeiro. Rio de Janeiro, Brasil. 


Rodolfo de Alkmim Moreira Nunes,

PhD. Universidade do Estado do Rio de Janeiro. Rio de Janeiro, Brasil. ORCID: 


Artigos mais lidos pelo mesmo(s) autor(es)

Antecedentes: O árbitro de futebol conduz os jogos à luz das regras do esporte, por isso é imperativo que esses profissionais acompanhem as propostas em uma posição o mais próximo possível dos movimentos, realizando caminhadas, trotes e corridas de alta intensidade. Na literatura, as variáveis hemodinâmicas acima mencionadas são medidas com um medidor de frequência com sistema de posicionamento global (GPS).

Objetivo: o objetivo deste estudo foi verificar o índice de reprodutibilidade do medidor de frequência com tecnologia GPS com velocidade de gravação de 1Hz em deslocamento acíclico e intensidade intermitente, realizado por árbitros de futebol.

Materiais e Métodos: Caracterizou-se um estudo de campo com caráter quantitativo, envolvendo 14 homens, com idade de 20,42 ± 2,78 anos, de um quartel na cidade do Rio de Janeiro. Foi utilizado monitor de frequência cardíaca polar com GPS de 1 Hz modelo V800. O protocolo utilizado foi adaptado do protocolo de teste da FIFA para árbitros de futebol, de modo que 10 "tiros" de 75m em 15s foram realizados por 25m em 20 de recuperação. Os testes e reteste foram aplicados com intervalo de 7 dias e protocolos idênticos: aquecimento, ambiente (4 "disparos" seguindo o modelo do protocolo acima) e depois o teste. Como o circuito coberto no protocolo de teste era de 1000 m.

Resultados: Foi obtida uma média de 1002,5 ± 17,12 m no teste e no teste 1010,83 ± 32,88 m, os coeficientes de variação foram respectivamente 1% e 3%. A diferença não foi significativa entre o teste e o reteste (valor P> 0,05), e o coeficiente de correlação intraclasse indicou associação moderada entre as medidas. Além disso, o valor do coeficiente de variação no teste e no reteste foi baixo, apresentando baixa dispersão.

Conclusão: Portanto, sugere-se que seja aceitável o uso de um medidor de frequência com velocidade de gravação de 1Hz para monitorar deslocamentos de árbitros de futebol em deslocamento acíclico e intensidade intermitente.


Visão geral 652 | Visualizações de PDF 49


Downloads

Os dados de download ainda não estão disponíveis.
  1. García RCF, de Oliveira RM, Martínez EC, Neves EB. VO2 Estimation Equation Accuracy to Young Adults. Arch Med (Manizales). 2020; 20(1):33-9.DOI: 10.30554/archmed.20.1.3476.2020
  2. Neves EB, Cunha RM, Rosa C, Antunes NS, Felisberto IMV, Vilaça-Alves J, et al. Correlation between skin temperature and heart rate during exercise and recovery, and the influence of body position in these variables in untrained women.Infrared Phys Technol. 2016; 75:70-6.DOI: 10.1016/j.infrared.2015.12.018 Publicación Anticipada
  3. Malone JJ, Lovell R, Varley MC, Coutts AJ. Unpacking the black box: applications and considerations for using GPS devices in sport. Int J Sports physiol Perform. 2017; 12(Suppl 2):S2-18-S2-26. DOI: 10.1123/ijspp.2016-0236
  4. Coutts AJ, Duffield R. Validity and reliability of GPS devices for measuring movement demands of team sports. J Sci Med Sport. 2010; 13(1):133-5. DOI: 10.1016/j.jsams.2008.09.015
  5. Jennings D, Cormack S, Coutts AJ, Boyd L, Aughey RJ. The validity and reliability of GPS units for measuring distance in team sport specific running patterns. Int J Sports physiol Perform. 2010; 5(3):328-41. DOI: 10.1123/ijspp.5.3.328
  6. Giles D, Draper N, Neil W. Validity of the Polar V800 heart rate monitor to measure RR intervals at rest. Eur J Appl Physiol. 2016; 116(3):563-71. DOI:10.1007/s00421-015-3303-9
  7. Caminal P, Sola F, Gomis P, Guasch E, Perera A, Soriano N, et al. Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions. Eur J Appl Physiol. 2018; 118(3):669-77. DOI:10.1007/s00421-018-3808-0
  8. Hernández-Vicente A, Santos-Lozano A, De Cocker K, Garatachea N. Validation study of Polar V800 accelerometer. Ann Transl Med. 2016; 4(15). DOI:10.21037/atm.2016.07.16
  9. Cunha RM, Arsa G, Neves EB, Lopes LC, Santana F, Noleto MV, et al. Water aerobics is followed by short-time and immediate systolic blood pressure reduction in overweight and obese hypertensive women. J Am Soc Hypertens. 2016; 10(7):570-7. DOI: 10.1016/j.jash.2016.05.002
  10. Bandeira F, Moura MAMd, Souza MAd, Nohama P, Neves EB. Pode a termografia auxiliar no diagnóstico de lesões musculares em atletas de futebol? Rev Bras Med Esporte. 2012; 18:246-51. DOI: 10.1590/S1517-86922012000400006
  11. Thomas JR, Nelson JK, Silverman SJ. Métodos de pesquisa em atividade física.6º ed.Porto Alegre: Artmed Editora; 2009.
  12. Resolução N. 466 do Conselho Nacional de Saúde. (Diário Oficial da União de 12 de dezembro de 2012).
  13. Bataller-Cervero AV, Gutierrez H, DeRentería J, Piedrafita E, Marcén N, Valero-Campo C, et al. Validity and reliability of a 10 Hz GPs for assessing variable and mean running speed. J Hum Kinet. 2019; 67(1):17-24. DOI: 10.2478/hukin-2018-0084
  14. Neves EB, Moreira TR, Lemos R, Vilaça-Alves J, Rosa C, Reis VM. Using skin temperature and muscle thickness to assess muscle response to strength training. Rev Bras Med Esporte. 2015; 21(5):350-4. DOI: 10.1590/1517-869220152105151293
  15. Neves EB, Matos F, da Cunha RM, Reis VM. Thermography to monitoring of Sports Training: an Overview. Pan Am J Med Thermol. 2015; 2(1):18-22. DOI: 10.18073/2358-4696/pajmt.v2n1p18-22 Publicación Anticipada
  16. Exército EM. Manual de treinamento físico militar (C 20 20). Brasília: EGCEEF; 2002.
  17. Fédération Internationale de Football Association (FIFA). 2020 Refereeing International Lists. Zurich: FIFA; 2020. [Accessed: 10 March 2020]. Available: https://resources.fifa.com/image/upload/2020-fifa-list-of-international-match-officials.pdf?cloudid=bdhkmbhyt2evwe69isju.
  18. Vieira S. Introdução à bioestatística. 4º ed. Rio de Janeiro: Elsevier Brasil; 2015.
  19. Lucini D, Marchetti I, Spataro A, Malacarne M, Benzi M, Tamorri S, et al. Heart rate variability to monitor performance in elite athletes: Criticalities and avoidable pitfalls. Int J Cardiol. 2017; 240:307-12. DOI: 10.1016/j.ijcard.2017.05.001
  20. de Lima L, Godoy ES, Neves EB, Vale R, López JAH, Nunes RdAM. Frecuencia cardíaca y la distancia recorrida por los árbitros de fútbol durante los partidos: una revisión sistemática. Arch Med Deporte. 2019; 189:36-42.
  21. Lima-e-Silva L, Neves E, Silva J, Alonso L, Vale R, Nunes R. The haemodynamic demand and the attributes related to the displacement of the soccer referees in the moments of decision/intervention during the matches. Int J Perform Anal Sport. 2020; 20(2):219-30. DOI: 10.1080/24748668.2020.1736937