The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity
The reproducibility of the 1hz gps in the aciclic displacement with intermittent intensity La reproducibilidad del gps de 1 hz en desplazamiento acíclico con intensidad intermitente
How to Cite
Download Citation

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Show authors biography
Most read articles by the same author(s)
- Rafael Chieza Fortes García, Rafael Melo de Oliveira, Eduardo Camilo Martínez, Eduardo Borba Neves, VO2 Estimation Equation Accuracy to Young Adults , Archivos de Medicina : Vol. 20 No. 1 (2020)
- Dryelle Soster Iede Shiguihara, Gleidson Brandão Oselame, Eduardo Borba Neves, Technologies for the Diagnosis of Radiodermatitis: a Systematic Review , Archivos de Medicina : Vol. 20 No. 2 (2020):
- Karielly Cássia de Almeida, Carmen Caroline Rasera, Wagner Luis Ripka, Tainá Ribas Mélo, Eduardo Borba Neves, RESPIRATORY FUNCTION IN CHILDREN WITH CEREBRAL PALSY , Archivos de Medicina : Vol. 23 No. 1 (2023): .
- Maria Elisa Koppke Miranda, Guillermo Brito Portugal, Bruno Ferreira Viana, Priscila dos Santos Bunn , Rodrigo Gomes de Souza Vale, Prediction of sleep quality in military submariners , Archivos de Medicina : Vol. 24 No. 2 (2024): Archivos de Medicina (Manizales)
Objective: the aim of this study was to verify the reproducibility index of the frequency meter with GPS technology with recording speed of 1Hz in acyclic displacement and intermittent intensity, performed by soccer referees. Materials and methods: it was characterized by a field study with a quantitative trait involving 14 men, aged 20.42 ± 2.78 years, from a barracks in the city of Rio de Janeiro. Polar heart rate monitor with 1Hz GPS model V800 was used. The protocol used was adapted from the FIFA test protocol for soccer referees, so that 10 "shots" of 75m in 15s were accomplished by 25m in 20 of recovery. Testing and retest were applied with 7 days interval and identical protocols: heating, ambiance (4 "shots" following the model of the protocol above) and then the test. Since the circuit covered in the test protocol was 1000 m.Results: a mean of 1002.5 ± 17.12 m was obtained in the test and in the test 1010.83± 32.88 m, the coefficients of variation were respectively 1% and 3%. The difference wasnot significant between the test and the retest (P-value> 0.05), and the intraclasscorrelation coefficient indicated a moderate association between the measures.Conclusion: therefore, it is suggested that it is acceptable to use a frequency gauge with a recording speed of 1Hz to monitor displacements of soccer referees in acyclic displacement and intermittent intensity.
Article visits 627 | PDF visits 44
Downloads
- García RCF, de Oliveira RM, Martínez EC, Neves EB. VO2 Estimation Equation Accuracy to Young Adults. Arch Med (Manizales). 2020; 20(1):33-9.DOI: 10.30554/archmed.20.1.3476.2020
- Neves EB, Cunha RM, Rosa C, Antunes NS, Felisberto IMV, Vilaça-Alves J, et al. Correlation between skin temperature and heart rate during exercise and recovery, and the influence of body position in these variables in untrained women.Infrared Phys Technol. 2016; 75:70-6.DOI: 10.1016/j.infrared.2015.12.018 Publicación Anticipada
- Malone JJ, Lovell R, Varley MC, Coutts AJ. Unpacking the black box: applications and considerations for using GPS devices in sport. Int J Sports physiol Perform. 2017; 12(Suppl 2):S2-18-S2-26. DOI: 10.1123/ijspp.2016-0236
- Coutts AJ, Duffield R. Validity and reliability of GPS devices for measuring movement demands of team sports. J Sci Med Sport. 2010; 13(1):133-5. DOI: 10.1016/j.jsams.2008.09.015
- Jennings D, Cormack S, Coutts AJ, Boyd L, Aughey RJ. The validity and reliability of GPS units for measuring distance in team sport specific running patterns. Int J Sports physiol Perform. 2010; 5(3):328-41. DOI: 10.1123/ijspp.5.3.328
- Giles D, Draper N, Neil W. Validity of the Polar V800 heart rate monitor to measure RR intervals at rest. Eur J Appl Physiol. 2016; 116(3):563-71. DOI:10.1007/s00421-015-3303-9
- Caminal P, Sola F, Gomis P, Guasch E, Perera A, Soriano N, et al. Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions. Eur J Appl Physiol. 2018; 118(3):669-77. DOI:10.1007/s00421-018-3808-0
- Hernández-Vicente A, Santos-Lozano A, De Cocker K, Garatachea N. Validation study of Polar V800 accelerometer. Ann Transl Med. 2016; 4(15). DOI:10.21037/atm.2016.07.16
- Cunha RM, Arsa G, Neves EB, Lopes LC, Santana F, Noleto MV, et al. Water aerobics is followed by short-time and immediate systolic blood pressure reduction in overweight and obese hypertensive women. J Am Soc Hypertens. 2016; 10(7):570-7. DOI: 10.1016/j.jash.2016.05.002
- Bandeira F, Moura MAMd, Souza MAd, Nohama P, Neves EB. Pode a termografia auxiliar no diagnóstico de lesões musculares em atletas de futebol? Rev Bras Med Esporte. 2012; 18:246-51. DOI: 10.1590/S1517-86922012000400006
- Thomas JR, Nelson JK, Silverman SJ. Métodos de pesquisa em atividade física.6º ed.Porto Alegre: Artmed Editora; 2009.
- Resolução N. 466 do Conselho Nacional de Saúde. (Diário Oficial da União de 12 de dezembro de 2012).
- Bataller-Cervero AV, Gutierrez H, DeRentería J, Piedrafita E, Marcén N, Valero-Campo C, et al. Validity and reliability of a 10 Hz GPs for assessing variable and mean running speed. J Hum Kinet. 2019; 67(1):17-24. DOI: 10.2478/hukin-2018-0084
- Neves EB, Moreira TR, Lemos R, Vilaça-Alves J, Rosa C, Reis VM. Using skin temperature and muscle thickness to assess muscle response to strength training. Rev Bras Med Esporte. 2015; 21(5):350-4. DOI: 10.1590/1517-869220152105151293
- Neves EB, Matos F, da Cunha RM, Reis VM. Thermography to monitoring of Sports Training: an Overview. Pan Am J Med Thermol. 2015; 2(1):18-22. DOI: 10.18073/2358-4696/pajmt.v2n1p18-22 Publicación Anticipada
- Exército EM. Manual de treinamento físico militar (C 20 20). Brasília: EGCEEF; 2002.
- Fédération Internationale de Football Association (FIFA). 2020 Refereeing International Lists. Zurich: FIFA; 2020. [Accessed: 10 March 2020]. Available: https://resources.fifa.com/image/upload/2020-fifa-list-of-international-match-officials.pdf?cloudid=bdhkmbhyt2evwe69isju.
- Vieira S. Introdução à bioestatística. 4º ed. Rio de Janeiro: Elsevier Brasil; 2015.
- Lucini D, Marchetti I, Spataro A, Malacarne M, Benzi M, Tamorri S, et al. Heart rate variability to monitor performance in elite athletes: Criticalities and avoidable pitfalls. Int J Cardiol. 2017; 240:307-12. DOI: 10.1016/j.ijcard.2017.05.001
- de Lima L, Godoy ES, Neves EB, Vale R, López JAH, Nunes RdAM. Frecuencia cardíaca y la distancia recorrida por los árbitros de fútbol durante los partidos: una revisión sistemática. Arch Med Deporte. 2019; 189:36-42.
- Lima-e-Silva L, Neves E, Silva J, Alonso L, Vale R, Nunes R. The haemodynamic demand and the attributes related to the displacement of the soccer referees in the moments of decision/intervention during the matches. Int J Perform Anal Sport. 2020; 20(2):219-30. DOI: 10.1080/24748668.2020.1736937