Objective: Analyze the microbiological quality of water services hospitalization, ICU and surgery two health institutions in the Eje Cafetero during the third quarter of 2015. Materials and methods: observational, cross-sectional study water samples were taken three critical points as are operating rooms, hospital and intensive care unit. One sample was performed prior to disinfection tap and another after disinfection to thereby determine if the filter installed on the taps influenced microbiological results, the samples were analyzed by membrane filtration. Results: We found that in one of the institutions there are large presences of molds and yeasts, mesophilic aerobic; in older and unviable before performing disinfection sanitary tap concentrations. And present in lower concentration post-disinfection possibly due to the lack of disinfection of storage tanks and faucets. In the second institution no significant counts of microorganisms were presented. Conclusions: an institution has health unfeasibly water in one of its critical points due to the high presence of molds and yeasts, and mesophilic aerobic, which precludes their consumption by decree 2115 of 2007, and international standards.
Article visits | PDF visits
Downloads
- Iglesias C, Villarino AL, Martínez JA, Cabrerizo L, Gargallo M, Lorenzo H. et al. Importancia del agua en la hidratación de la población española. Nutrición Hospitalaria 2010: 27-36.
- Montes AM, Calidad del agua potable del Hospital de Ginecología y Obstetricia del Instituto Materno Infantil del Estado de México. Archivos de investigación materno infantil 2013; 4(3): 139-142.
- Orozco PA, Cortés, JA, Parra CM. Colonización por levaduras en recién nacidos y personal de salud en la unidad de cuidados intensivos neonatales de un hospital universitario en Bogotá, Colombia.Revista Iberoamericana de Micología 2009; 26(2), 108-111.
- Cárdenas MX, Cortes JA, Parra CM. Presencia de aspergiullus spp. En áreas de riesgo en pacientes trasplantados en un hospital universitario. Revista Iberoamericana de Micología 2008; 25: 232-236
- Red Nacional de Vigilancia de la Resistencia Bacteriana y de las Infecciones Asociadas al Cuidado de la salud. Estado del arte de la resistencia bacteriana y la vigilancia epidemiológica de las infecciones asociadas al cuidado de la salud en Colombia.2009
- Organización Mundial de la Salud. Prevención de las infecciones nosocomiales. Guía práctica OMS 2003.
- Programa de las Naciones Unidas para el medio ambiente. Índice e indicadores de la calidad del agua
- Pegues DA, Arathoon EG, Samayoa B. Epidemic gramnegative bacteriemia in a neonatal unit in Guatemala. Am J infect Control 1994; 22: 163-71
- Ministerio De La Protección Social Ministerio De Ambiente, Vivienda Y Desarrollo Territorial. (2007). Características, instrumentos básicos y frecuencias del sistema de control y vigilancia para la calidad del agua para consumo humano. Resolución Número 2115 de 2007.
- Organización Mundial de la Salud. Guías para la calidad del agua potable. Primer apéndice a la tercera edición 2006. Ginebra, Suiza.
- Cerda LJ, Valdivia CG. John Snow, la epidemia de cólera y el nacimiento de la epidemiología moderna. Revista chilena de infectología 2007; 24(4): 331-334.
- Gómez OG. Enfermedad diarreica aguda por Escherichia coli enteropatógenas en Colombia. Revista chilena de infectología 2014; 31(5): 577-586.
- Corrales MJ, Gea MT, Limón R, Miralles JJ, Requena J, Aranaz JM, et al. Factors that contribute to health care associated infections: how to prevent them. Rev Calidad asistencial 2011; 367–75.
- Fernández JA, Marco T, Orozco D, Merino J. El hospital ante un brote prolongado de legionelosis. Gaceta Sanitaria 2004; 18(4): 335-337.
- Hernández GI, Saenz MC, Melendez D. Evaluación de un programa formativo para la prevención de las infecciones relacionadas con la asistencia sanitaria. Revista calidad asistencial 2013: 96–108.
- Bartram J. Flowing away: water andhealth opportunities. Bull World Health 2008; 86(1): 2-3.
- Macías AE, Monroy R, Muñoz M, Medina H, Ponce S. Cloración y contaminación bacteriana. Aguas turbulentas en los hospitales. Revista Investigación clínica 2006; 58(5): 470-474.
- Vargas S., Romero JJ, Prada Y, Fonseca G, Lao W. Factores de riesgo para el desarrollo de infecciones intrahospitalarias en pacientes quemados. Hospital San Juan de Dios, Costa Rica: Enero 2003-Diciembre 2005. Parte I. Cirugía plástica iberolatinoamerica 2009; 35(3): 223-232. Disponible en:
- Pérez P, Herrera M, Bueno A, Alonso MS, Buiza B, Vásquez M. Higiene de las manos: conocimientos de los profesionales y áreas de mejora. Cad Saúde Pública 2015; 31(1): 149-160.
- Moreno B. Rodrigo, Riquelme O. Raúl. Etiología de la neumonía adquirida en la comunidad en el adulto inmunocompetente. Revista chilena de infectología 2005; 22:18-25.
- Mora Alvarado DA. Processing and proposal of microbiological criteria to evaluate water of introhospitable human consumption in Costa Rica. Rev cienc adm Financ segur soc 2000; 40–50.
- García M, Mariné MA Desarrollo de una herramienta metodológica para perfeccionar la vigilancia de la calidad sanitaria del agua para hemodiálisis. Rev Cubana Hig Epidemiol 2010, 48(2): 133-141.
- Macias AE, Muñoz JM, Bruckner DA. Parenteral infusions bacterial contamination in a multi–institutional survey in Mexico: Considerations for nosocomial mortality. Am J Infect Control 1999; 27: 285–90.